Products / Cardiothoracic / Ortolog Cables
ORTHOLOX
Ortolog Cables
Sternal closure cable system
A cable-based sternal closure system engineered to distribute load evenly across the sternum, providing secure fixation after median sternotomy.
-
Even load distribution reduces bone cut-through risk
-
Consistent, reproducible tensioning
-
Designed for routine and high-risk sternotomy closure
OVERVIEW
About this product
Ortolog Cables replace conventional stainless steel wire with a multi-filament cable that spreads closure force over a broader bone surface. Where a single-strand wire concentrates load on a narrow contact line, the braided cable conforms to the sternal cortex and reduces the peak pressure that drives cut-through in osteoporotic, obese or re-operative patients.
Each cable is supplied pre-mounted to a swaged needle and paired with a crimp lock, so the surgeon can pass, tension and secure the closure in a reproducible sequence. Tension is applied with a dedicated tensioner and captured mechanically by the lock, removing the variability of hand-twisted wire knots.
The system is designed to sit flat against bone, minimising palpable prominence and soft-tissue irritation, and is fully compatible with standard sternal re-entry techniques should re-operation be required.
PRODUCT DETAILS
Family
Cardiothoracic
Supplier
Ortholox
Availability
Australia & New Zealand
FEATURES
Key features and benefits
Multi-filament cable construction
Braided strands flex around the sternal edge and distribute closure force over a wider footprint than single-strand wire.
Mechanical crimp lock
Tension set by the tensioner is captured by the lock, so closure force does not depend on knot technique.
Low-profile fixation
Cable and lock sit close to bone, limiting palpable hardware and soft-tissue irritation in thin patients.
Re-entry friendly
Cables can be cut and removed with standard instruments if sternal re-entry becomes necessary.
CLINICAL USE
Applications and indications
Routine median sternotomy
Primary closure after coronary artery bypass grafting, valve surgery and aortic procedures.
High-risk sternal closure
Osteoporotic bone, elevated BMI, diabetes, COPD and other patients at raised risk of sternal dehiscence.
Re-do and revision surgery
Re-closure after sternal re-entry, including cases with existing bone loss or previous wire cut-through.
MEDIAN STERNOTOMY CLOSURE
HIGH-RISK AND RE-DO STERNAL CLOSURE
SPECIFICATION
Specifications, sizes and models
Implant material
Implant-grade metal cable with matched crimp lock
Delivery
Cable pre-attached to a swaged needle
Fixation
Mechanical crimp, tensioner-controlled
Sterility
Supplied sterile, single use
Imaging
Radio-opaque; visible on chest radiograph
Standard cable
Single peristernal cable for routine closure
Cable set
Multi-cable pack covering a full sternotomy closure sequence
Instrument set
Reusable tensioner and crimper supplied for theatre sterilisation
TECHNICAL
Important technical information
-
Place cables peristernally or transsternally according to bone quality and surgeon preference; a typical closure uses five to seven cables.
-
Apply tension progressively and symmetrically from the manubrium downward to avoid shear at the sternal midline.
-
Crimp only once tension is confirmed — a crimped lock is not intended to be re-tensioned.
-
Trim excess cable and turn the free end away from the skin to avoid soft-tissue irritation.
-
Reusable instruments must be cleaned and sterilised in line with the supplier's reprocessing instructions.
RESOURCES
Surgical technique guide
Available on request from MediGroup EBI
Product and ordering catalogue
PDF supplied by our clinical team
In-service theatre training
Scheduled with your hospital
ACCESSORIES
-
Cable tensioner
-
Crimping instrument
-
Cable cutter
This page is a clinical summary for healthcare professionals. Always refer to the manufacturer's instructions for use for full indications, contraindications, warnings and handling requirements.